English
Language : 

AMIC110 Datasheet, PDF (69/214 Pages) Texas Instruments – Sitara Processors
www.ti.com
AMIC110
SPRS971A – AUGUST 2016 – REVISED SEPTEMBER 2016
5.3 Power-On Hours (POH)
NOTE
Industrial Extended temperature is not supported for this family of devices.
Table 5-1. Reliability Data(1)(2)(3)(4)
OPERATING
CONDITION
Nitro
COMMERCIAL
JUNCTION
TEMP (TJ)
0°C to 90°C
LIFETIME
(POH)(5)
100K
INDUSTRIAL
JUNCTION
TEMP (TJ)
–40°C to 90°C
LIFETIME
(POH)(5)
100K
EXTENDED
JUNCTION
TEMP (TJ)
–40°C to 105°C
LIFETIME
(POH)(5)
37K
INDUSTRIAL EXTENDED
JUNCTION
TEMP (TJ)
–40°C to 125°C
LIFETIME
(POH)(5)
–
Turbo
0°C to 90°C
100K –40°C to 90°C 100K –40°C to 105°C
80K
–40°C to 125°C
–
OPP120
0°C to 90°C
100K –40°C to 90°C 100K –40°C to 105°C 100K –40°C to 125°C
–
OPP100
0°C to 90°C
100K –40°C to 90°C 100K –40°C to 105°C 100K –40°C to 125°C
35K
OPP50
0°C to 90°C
100K –40°C to 90°C 100K –40°C to 105°C 100K –40°C to 125°C
95K
(1) The power-on hours (POH) information in this table is provided solely for your convenience and does not extend or modify the warranty
provided under TI's standard terms and conditions for TI semiconductor products.
(2) To avoid significant degradation, the device power-on hours (POH) must be limited as described in this table.
(3) Logic functions and parameter values are not assured out of the range specified in the recommended operating conditions.
(4) The previous notations cannot be deemed a warranty or deemed to extend or modify the warranty under TI's standard terms and
conditions for TI semiconductor products.
(5) POH = Power-on hours when the device is fully functional.
5.4 Operating Performance Points (OPPs)
Device OPPs are defined in Table 5-2 through Table 5-9.
NOTE
• 300 MHz is the maximum frequency supported for this family of devices.
• The ZCE package is not supported for this family of devices.
Table 5-2. VDD_CORE OPPs for ZCZ Package
With Device Revision Code "Blank"
NOTE
Device Revision Code "Blank" is not supported for this family of devices.
Table 5-3. VDD_MPU OPPs for ZCZ Package
With Device Revision Code "Blank"
NOTE
Device Revision Code "Blank" is not supported for this family of devices.
Copyright © 2016, Texas Instruments Incorporated
Submit Documentation Feedback
Product Folder Links: AMIC110