26. Electrical Characteristics
[Operating Precautions]
The inputs and outputs are asynchronous in asynchronous mode, but as shown in figure 26.20, the
received data is considered to have been changed at CK clock rise (two-clock intervals). The
transmit signals change with a reference of CK clock rise (two-clock intervals).
SCK0 to SCK3
tsckw
VIH
VIH
VIL
tsckr
VIH
VIL
tscyc
tsckf
VIH
VIL
Figure 26.19 SCI Input Timing
SCI input/output timing (clock synchronous mode)
tscyc
SCK0 to SCK3
(input/output)
tTxD
TxD0 to TxD3
(transmit data)
RxD0 to RxD3
(received data)
tRxS tRxH
SCI input/output timing (asynchronous mode)
T1
VOH
CK
tTxD
TxD0 to TxD3
(transmit data)
RxD0 to RxD3
(received data)
Tn
VOH
tRxS tRxH
Figure 26.20 SCI Input/Output Timing
Rev.4.00 Mar. 27, 2008 Page 787 of 882