11. Multi-Function Timer Pulse Unit (MTU)
Timing for Counter Clearing by Compare Match/Input Capture: Figure 11.60 shows the
timing when counter clearing on compare match is specified, and figure 11.61 shows the timing
when counter clearing on input capture is specified.
Pφ
Compare
match signal
Counter
clear signal
TCNT
N
H'0000
TGR
N
Figure 11.60 Counter Clear Timing (Compare Match)
Pφ
Input capture
signal
Counter clear
signal
TCNT
N
H'0000
TGR
N
Figure 11.61 Counter Clear Timing (Input Capture)