11. Multi-Function Timer Pulse Unit (MTU)
Operation when Error Occurs during Normal Mode Operation, and Operation is Restarted
in PWM Mode 1: Figure 11.86 shows an explanatory diagram of the case where an error occurs
in normal mode and operation is restarted in PWM mode 1 after re-setting.
1
2
3
RESET TMDR TOER
(normal) (1)
4
TIOR
(1 init
0 out)
5
6
PFC TSTR
(MTU) (1)
7
8
9
10 11 12
Match Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM1) (1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
MTU module output
TIOC*A
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
Hi-Z
PEn
Hi-Z
n=0 to 15
Figure 11.86 Error Occurrence in Normal Mode, Recovery in PWM Mode 1
1 to 10 are the same as in figure 11.85.
11. Set PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized. If
initialization is required, initialize in normal mode, then switch to PWM mode 1.)
13. Set MTU output with the PFC.
14. Operation is restarted by TSTR.
Rev.4.00 Mar. 27, 2008 Page 340 of 882
REJ09B0108-0400