11. Multi-Function Timer Pulse Unit (MTU)
Operation when Error Occurs during PWM Mode 2 Operation, and Operation is Restarted
in PWM Mode 1: Figure 11.98 shows an explanatory diagram of the case where an error occurs
in PWM mode 2 and operation is restarted in PWM mode 1 after re-setting.
1
2
3
RESET TMDR TIOR
(PWM2) (1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
10 11
Error PFC TSTR TMDR TIOR
occurs (PORT) (0) (PWM1) (1 init
0 out)
12
PFC
(MTU)
13
TSTR
(1)
MTU module output
TIOC*A
Not initialized (cycle register)
TIOC*B
Not initialized (TIOC*B)
Port output
PEn
Hi-Z
PEn
Hi-Z
n=0 to 15
Figure 11.98 Error Occurrence in PWM Mode 2, Recovery in PWM Mode 1
1 to 9 are the same as in figure 11.97.
10. Set PWM mode 1.
11. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized.)
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev.4.00 Mar. 27, 2008 Page 352 of 882
REJ09B0108-0400