English
Language : 

HD64F7144F50V Datasheet, PDF (400/932 Pages) Renesas Technology Corp – Old Company Name in Catalogs and Other Documents
11. Multi-Function Timer Pulse Unit (MTU)
Operation when Error Occurs during PWM Mode 2 Operation, and Operation is Restarted
in Phase Counting Mode: Figure 11.100 shows an explanatory diagram of the case where an
error occurs in PWM mode 2 and operation is restarted in phase counting mode after re-setting.
MTU module output
TIOC*A
1
2
3
RESET TMDR TIOR
(PWM2) (1 init
0 out)
4
PFC
(MTU)
5
TSTR
(1)
6
Match
7
8
9
Error PFC TSTR
occurs (PORT) (0)
10
TMDR
(PCM)
11
TIOR
(1 init
0 out)
Not initialized (cycle register)
12 13
PFC TSTR
(MTU) (1)
TIOC*B
Port output
PEn
Hi-Z
PEn
Hi-Z
n=0 to 15
Figure 11.100 Error Occurrence in PWM Mode 2, Recovery in Phase Counting Mode
1 to 9 are the same as in figure 11.97.
10. Set phase counting mode.
11. Initialize the pins with TIOR.
12. Set MTU output with the PFC.
13. Operation is restarted by TSTR.
Rev.4.00 Mar. 27, 2008 Page 354 of 882