SCI
To determine the value of a data bit and to detect noise, recovery logic
takes samples at RT8, RT9, and RT10. Table 6 summarizes the results
of the data bit samples.
Table 6. Data Bit Recovery
RT8, RT9, and RT10 Samples
000
001
010
011
100
101
110
111
Data Bit Determination
0
0
0
1
0
1
1
1
Noise Flag
0
1
1
1
1
1
1
0
NOTE:
The RT8, RT9, and RT10 samples do not affect start bit verification. If
any or all of the RT8, RT9, and RT10 start bit samples are logic 1s
following a successful start bit verification, the noise flag (NF) is set and
the receiver assumes that the bit is a start bit.