English
Language : 

ATMEGA8U2_14 Datasheet, PDF (265/310 Pages) ATMEL Corporation – 125 Powerful Instructions – Most Single Clock Cycle Execution
ATmega8U2/16U2/32U2
TA = -40C to 85C, VCC = 2.7V to 5.5V (unless otherwise noted) (Continued)
Symbol Parameter
Condition
Min.(5)
Typ.
Max.(5)
Units
RPUDP
USB D+ Internal Pull-Up
Idle mode
Streaming mode
900
1425
1500

3090

Active 8 MHz, VCC = 3V
regulator disabled
4
6
mA
Power Supply Current(6)
Active 16 MHz, VCC = 5V
regulator enabled
Idle 8 MHz, VCC = 3V
regulator disabled
13.5
21
mA
0.8
1.2
mA
Idle 16 MHz, VCC = 5V
regulator enabled
3.2
4.0
mA
ICC
Power-down mode
WDT disabled, regulator
disabled,VCC = 3V
WDT enabled, regulator
disabled,VCC = 3V
WDT, BOD, regulator
enabled, Vcc = 5V
5
10
μA
10
15
μA
40
65
μA
WDT disabled, BOD
Enabled, regulator disabled,
250
μA
Standby mode - 8MHZ
Vcc = 3V
XTAL
WDT disabled, BOD,
regulator enabled, Vcc = 5V
350
μA
VACIO
IACLK
tACID
Rusb
Analog Comparator
Input Offset Voltage
Analog Comparator
Input Leakage Current
Analog Comparator
Propagation Delay
USB Series resistor
(external)
VCC = 5V
Vin = VCC/2
VCC = 5V
Vin = VCC/2
VCC = 2.7V
VCC = 4.0V
<10
40
mV
-50
50
nA
750
500
ns
22±5%

Vreg
Regulator Output Voltage
Vcc 4.0V, I100mA,
CUCAP=1μF±20%
3.0
3.3
3.6
V
UVcc
4
Note: 1. "Max" means the highest value where the pin is guaranteed to be read as low
5.5
V
2. "Min" means the lowest value where the pin is guaranteed to be read as high
3. Although each I/O port can sink more than the test conditions (20mA at VCC = 5V, 10mA at VCC = 3V) under steady state
conditions (non-transient), the following must be observed:
1.)The sum of all IOL, for ports B0-B7, C0-C7, D0-D7 should not exceed 150 mA.
If IOL exceeds the test condition, VOL may exceed the related specification. Pins are not guaranteed to sink current greater
than the listed test condition.
4. Although each I/O port can source more than the test conditions (20mA at VCC = 5V, 10mA at VCC = 3V) under steady
state conditions (non-transient), the following must be observed:
1.)The sum of all IOL, for ports B0-B7, C0-C7, D0-D7 should not exceed 150 mA.
If IOH exceeds the test condition, VOH may exceed the related specification. Pins are not guaranteed to source current
greater than the listed test condition.
7799D–AVR–11/10
265