English
Language : 

C509-L_97 Datasheet, PDF (273/290 Pages) Siemens Semiconductor Group – 8-Bit CMOS Microcontroller
Device Specifications
C509-L
Power Supply Current
Parameter
Active mode
Idle mode
Power-down mode
12 MHz
16 MHz
12 MHz
16 MHz
Symbol Limit Values
typ. 9)
max. 10)
ICC
31
37
ICC
41
50
ICC
19
23
ICC
24
31
IPD
30
50
Unit Test Condition
mA 4)
mA
mA 5)
mA
µA VCC = 2…5.5 V 3)
Notes :
1) Capacitive loading on ports 0 and 2 may cause spurious noise pulses to be superimposed on the VOL of ALE
and port 1, 3, 4, 5, 6, and 9. The noise is due to external bus capacitance discharging into the port 0 and port
2 pins when these pins make 1-to-0 transitions during bus operation. In the worst case (capacitive loading
> 100 pF), the noise pulse on ALE line may exceed 0.8 V. In such cases it may be desirable to qualify ALE
with a schmitt-trigger, or use an address latch with a schmitt-trigger strobe input.
2) Capacitive loading on ports 0 and 2 may cause the VOH on ALE and PSEN/RDF to momentarily fall below the
0.9 VCC specification when the address lines are stabilizing.
3) IPD (power down mode) is measured under following conditions:
EA = RESET = VCC; Port0 = Port7 = Port8 = VCC; XTAL1 = N.C.; XTAL2 = VSS; PE/SWD = OWE = VSS;
HWDP = VCC; VAREF = VCC; VAGND = VSS; all other pins are disconnected.
Hardware power down mode current (IPD) is measured with OWE =VCC or VSS.
4) ICC (active mode) is measured with:
XTAL2 driven with tR/tF = 5 ns , VIL = VSS + 0.5 V, VIH = VCC – 0.5 V; XTAL1 = N.C.; EA = PE/SWD= VCC ;
Port0 = Port7 = Port8 = VCC ; HWPD = VCC ; RESET = VSS; all other pins are disconnected. ICC would be
slightly higher if a crystal oscillator is used.
5) ICC (idle mode) is measured with all output pins disconnected and with all peripherals disabled;
XTAL2 driven with tR/tF = 5 ns, VIL = VSS + 0.5 V, VIH = VCC – 0.5 V; XTAL1 = N.C.; RESET = VCC;
HWPD = VCC ; Port0 = Port7 = Port8 = VCC ; EA = PE/SWD = VSS; all other pins are disconnected;
6) Input leakage current for port 0 is measured with RESET = VCC.
7) Overload conditions occur if the standard operating conditions are exeeded, ie. the voltage on any pin exceeds
the specified range (i.e. VOV > VCC + 0.5 V or VOV < VSS - 0.5 V). The supply voltage VCC and VSS must remain
within the specified limits. The absolute sum of input currents on all port pins may not exceed 50 mA.
8) Not 100% tested, guaranteed by design characterization.
9) The typical ICC values are periodically measured at TA = +25 ˚C and VCC = 5 V but not 100% tested.
10)The maximum ICC values are measured under worst case conditions (TA = 0 ˚C or -40 ˚C and VCC = 5.5 V)
Semiconductor Group
11-3
1997-10-01