MC908AZ60ACFUER Datasheet, PDF (274/414 Pages) Freescale Semiconductor, Inc – To provide the most up-to-date information, the revision of our documents on the World Wide Web will be the most current. Your printed copy may be an earlier revision. To verify you have the latest information available, refer to:
MSCAN Controller (MSCAN08)
23.6 Interrupts
The MSCAN08 supports four interrupt vectors mapped onto eleven different interrupt sources, any of
which can be individually masked (for details see 23.13.5 MSCAN08 Receiver Flag Register (CRFLG), to
23.13.8 MSCAN08 Transmitter Control Register).
• Transmit Interrupt: At least one of the three transmit buffers is empty (not scheduled) and can be
loaded to schedule a message for transmission. The TXE flags of the empty message buffers are
set.
• Receive Interrupt: A message has been received successfully and loaded into the foreground
receive buffer. This interrupt will be emitted immediately after receiving the EOF symbol. The RXF
flag is set.
• Wakeup Interrupt: An activity on the CAN bus occurred during MSCAN08 internal sleep mode or
power-down mode (provided SLPAK = WUPIE = 1).
• Error Interrupt: An overrun, error, or warning condition occurred. The receiver flag register
(CRFLG) will indicate one of the following conditions:
– Overrun: An overrun condition as described in 23.4.2 Receive Structures, has occurred.
– Receiver Warning: The receive error counter has reached the CPU Warning limit of 96.
– Transmitter Warning: The transmit error counter has reached the CPU Warning limit of 96.
– Receiver Error Passive: The receive error counter has exceeded the error passive limit of 127
and MSCAN08 has gone to error passive state.
– Transmitter Error Passive: The transmit error counter has exceeded the error passive limit of
127 and MSCAN08 has gone to error passive state.
– Bus Off: The transmit error counter has exceeded 255 and MSCAN08 has gone to bus off state.
23.6.1 Interrupt Acknowledge
Interrupts are directly associated with one or more status flags in either the MSCAN08 receiver flag
register (CRFLG) or the MSCAN08 transmitter flag register (CTFLG). Interrupts are pending as long as
one of the corresponding flags is set. The flags in the above registers must be reset within the interrupt
handler in order to handshake the interrupt. The flags are reset through writing a ‘1’ to the corresponding
bit position. A flag cannot be cleared if the respective condition still prevails.
NOTE
Bit manipulation instructions (BSET) shall not be used to clear interrupt
flags.