MC908AZ60ACFUER Datasheet, PDF (224/414 Pages) Freescale Semiconductor, Inc – To provide the most up-to-date information, the revision of our documents on the World Wide Web will be the most current. Your printed copy may be an earlier revision. To verify you have the latest information available, refer to:
Serial Peripheral Interface (SPI)
For an idle master or idle slave that has no data loaded into its transmit buffer, the SPTE will be set
again within two bus cycles since the transmit buffer empties into the shift register. This allows the user
to queue up a 16-bit value to send. For an already active slave, the load of the shift register cannot
occur until the transmission is completed. This implies that a back-to-back write to the transmit data
register is not possible. The SPTE indicates when the next write can occur.
Reset sets the SPTE bit.
1 = Transmit data register empty
0 = Transmit data register not empty
MODFEN — Mode Fault Enable Bit
This read/write bit, when set to 1, allows the MODF flag to be set. If the MODF flag is set, clearing the
MODFEN does not clear the MODF flag. If the SPI is enabled as a master and the MODFEN bit is low,
then the SS pin is available as a general-purpose I/O.
If the MODFEN bit is set, then this pin is not available as a general purpose I/O. When the SPI is
enabled as a slave, the SS pin is not available as a general-purpose I/O regardless of the value of
MODFEN. (See 19.12.4 SS (Slave Select)).
If the MODFEN bit is low, the level of the SS pin does not affect the operation of an enabled SPI
configured as a master. For an enabled SPI configured as a slave, having MODFEN low only prevents
the MODF flag from being set. It does not affect any other part of SPI operation. (See 19.6.2 Mode
Fault Error).
SPR1 and SPR0 — SPI Baud Rate Select Bits
In master mode, these read/write bits select one of four baud rates as shown in Table 19-5. SPR1 and
SPR0 have no effect in slave mode. Reset clears SPR1 and SPR0.
Table 19-5. SPI Master Baud Rate Selection
SPR1:SPR0
00
01
10
11
Baud Rate Divisor (BD)
2
8
32
128
Use this formula to calculate the SPI baud rate:
Baud rate = C-----2G----M×-----B-O----DU-----T--
where:
CGMOUT = base clock output of the clock generator module (CGM),
see Chapter 10 Clock Generator Module (CGM).
BD = baud rate divisor
MC68HC908AZ60A • MC68HC908AS60A • MC68HC908AS60E Data Sheet, Rev. 6
224