MC908AZ60ACFUER Datasheet, PDF (214/414 Pages) Freescale Semiconductor, Inc – To provide the most up-to-date information, the revision of our documents on the World Wide Web will be the most current. Your printed copy may be an earlier revision. To verify you have the latest information available, refer to:
Serial Peripheral Interface (SPI)
The first part of Figure 19-7 shows how to read the SPSCR and SPDR to clear the SPRF without
problems. However, as illustrated by the second transmission example, the OVRF flag can be set in
between the time that SPSCR and SPDR are read.
In this case, an overflow can be easily missed. Since no more SPRF interrupts can be generated until this
OVRF is serviced, it will not be obvious that bytes are being lost as more transmissions are completed.
To prevent this, either enable the OVRF interrupt or do another read of the SPSCR after the read of the
SPDR. This ensures that the OVRF was not set before the SPRF was cleared and that future
transmissions will complete with an SPRF interrupt. Figure 19-8 illustrates this process. Generally, to
avoid this second SPSCR read, enable the OVRF to the CPU by setting the ERRIE bit (SPSCR).
BYTE 1
SPI RECEIVE
1
COMPLETE
SPRF
BYTE 2
5
BYTE 3
7
BYTE 4
11
OVRF
READ SPSCR
2
4
6
9
12
14
READ SPDR
3
8
10
13
1 BYTE 1 SETS SPRF BIT.
2 CPU READS SPSCR WITH SPRF BIT SET
AND OVRF BIT CLEAR.
3 CPU READS BYTE 1 IN SPDR,
CLEARING SPRF BIT.
4 CPU READS SPSCR AGAIN
TO CHECK OVRF BIT.
5 BYTE 2 SETS SPRF BIT.
6 CPU READS SPSCR WITH SPRF BIT SET
AND OVRF BIT CLEAR.
7 BYTE 3 SETS OVRF BIT. BYTE 3 IS LOST.
8 CPU READS BYTE 2 IN SPDR,
CLEARING SPRF BIT.
9 CPU READS SPSCR AGAIN
TO CHECK OVRF BIT.
10 CPU READS BYTE 2 SPDR,
CLEARING OVRF BIT.
11 BYTE 4 SETS SPRF BIT.
12 CPU READS SPSCR.
13 CPU READS BYTE 4 IN SPDR,
CLEARING SPRF BIT.
14 CPU READS SPSCR AGAIN
TO CHECK OVRF BIT.
Figure 19-8. Clearing SPRF When OVRF Interrupt Is Not Enabled
19.6.2 Mode Fault Error
For the MODF flag (in SPSCR) to be set, the mode fault error enable bit (MODFEN in SPSCR) must be
set. Clearing the MODFEN bit does not clear the MODF flag but does prevent MODF from being set again
after MODF is cleared.
MODF generates a receiver/error CPU interrupt request if the error interrupt enable bit (ERRIE in SPSCR)
is also set. The SPRF, MODF, and OVRF interrupts share the same CPU interrupt vector. MODF and
OVRF can generate a receiver/error CPU interrupt request. (See Figure 19-9). It is not possible to enable
only MODF or OVRF to generate a receiver/error CPU interrupt request. However, leaving MODFEN low
prevents MODF from being set.