English
Language : 

MC68HC908EY16 Datasheet, PDF (236/278 Pages) Motorola, Inc – Microcontrollers
Development Support
Table 19-1 also lists external frequencies required to achieve a standard baud rate of 7200 bps. The
effective baud rate is the bus frequency divided by 278. If using a crystal as the clock source, be aware
of the upper frequency limit that the internal clock module can handle. See 20.6 Control Timing for this
limit.
19.3.1.7 Commands
The monitor ROM firmware uses these commands:
• READ (read memory)
• WRITE (write memory)
• IREAD (indexed read)
• IWRITE (indexed write)
• READSP (read stack pointer)
• RUN (run user program)
The monitor ROM firmware echoes each received byte back to the PTA0 pin for error checking. An 11-bit
delay at the end of each command allows the host to send a break character to cancel the command. A
delay of two bit times occurs before each echo and before READ, IREAD, or READSP data is returned.
The data returned by a read command appears after the echo of the last byte of the command.
NOTE
Wait one bit time after each echo before sending the next byte.
FROM
HOST
READ
READ
ADDRESS ADDRESS ADDRESS ADDRESS
HIGH
HIGH
LOW
LOW
4
1
4
1
4
1
3, 2
ECHO
Notes:
1 = Echo delay, approximately 2 bit times
2 = Data return delay, approximately 2 bit times
3 = Cancel command delay, 11 bit times
4 = Wait 1 bit time before sending next byte.
Figure 19-14. Read Transaction
FROM
HOST
DATA
4
RETURN
WRITE
WRITE
ADDRESS ADDRESS ADDRESS ADDRESS
HIGH
HIGH
LOW
LOW
DATA
DATA
3
1
3
1
3
1
3
1
2, 3
ECHO
Notes:
1 = Echo delay, approximately 2 bit times
2 = Cancel command delay, 11 bit times
3 = Wait 1 bit time before sending next byte.
Figure 19-15. Write Transaction
MC68HC908EY16 • MC68HC908EY8 Data Sheet, Rev. 10
236
Freescale Semiconductor