dsPIC33EPXXX(GP/MC/MU)806/810/814 and PIC24EPXXX(GP/GU)810/814
REGISTER 6-1: RCON: RESET CONTROL REGISTER(1)
R/W-0
R/W-0
U-0
TRAPR
IOPUWR
—
bit 15
U-0
R/W-0
U-0
—
VREGSF
—
R/W-0
CM
R/W-0
VREGS
bit 8
R/W-0
EXTR
bit 7
R/W-0
SWR
R/W-0
SWDTEN(2)
R/W-0
WDTO
R/W-0
SLEEP
R/W-0
IDLE
R/W-1
BOR
R/W-1
POR
bit 0
Legend:
R = Readable bit
-n = Value at POR
W = Writable bit
‘1’ = Bit is set
U = Unimplemented bit, read as ‘0’
‘0’ = Bit is cleared
x = Bit is unknown
bit 15
bit 14
bit 13-12
bit 11
bit 10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
TRAPR: Trap Reset Flag bit
1 = A Trap Conflict Reset has occurred
0 = A Trap Conflict Reset has not occurred
IOPUWR: Illegal Opcode or Uninitialized W Access Reset Flag bit
1 = An illegal opcode detection, an illegal address mode or uninitialized W register used as an
Address Pointer caused a Reset
0 = An illegal opcode or uninitialized W Reset has not occurred
Unimplemented: Read as ‘0’
VREGSF: Flash Voltage Regulator Standby During Sleep bit
1 = Flash voltage regulator is active during Sleep
0 = Flash voltage regulator goes into Standby mode during Sleep
Unimplemented: Read as ‘0’
CM: Configuration Mismatch Flag bit
1 = A Configuration Mismatch Reset has occurred.
0 = A Configuration Mismatch Reset has NOT occurred
VREGS: Voltage Regulator Standby During Sleep bit
1 = Voltage regulator is active during Sleep
0 = Voltage regulator goes into Standby mode during Sleep
EXTR: External Reset (MCLR) Pin bit
1 = A Master Clear (pin) Reset has occurred
0 = A Master Clear (pin) Reset has not occurred
SWR: Software Reset (Instruction) Flag bit
1 = A RESET instruction has been executed
0 = A RESET instruction has not been executed
SWDTEN: Software Enable/Disable of WDT bit(2)
1 = WDT is enabled
0 = WDT is disabled
WDTO: Watchdog Timer Time-out Flag bit
1 = WDT time-out has occurred
0 = WDT time-out has not occurred
Note 1:
2:
All of the Reset status bits can be set or cleared in software. Setting one of these bits in software does not
cause a device Reset.
If the FWDTEN Configuration bit is ‘1’ (unprogrammed), the WDT is always enabled, regardless of the
SWDTEN bit setting.
 2009-2012 Microchip Technology Inc.