English
Language : 

Z8FMC16100 Datasheet, PDF (345/402 Pages) Zilog, Inc. – Z8 Encore-R Motor Control Flash MCUs
Z8FMC16100 Series Flash MCU
Product Specification
323
Bit
Position
Value
(H)
Description
[4]
Fault1RST 0
Fault 1 Restart
Automatic recovery. PWM resumes control of outputs when all fault sources have
deasserted.
1
Software controlled recovery. PWM resumes control of outputs only after all fault
sources have deasserted and all fault flags are cleared and a PWM reload occurs
[3
CMP0INT 0
Comparator 0 Interrupt
Interrupt on comparator 0 assertion disabled.
1
Interrupt on comparator 0 assertion enabled.
[2]
CMP0RST 0
Comparator 0 Restart
Automatic recovery. PWM resumes control of outputs when all fault sources have
deasserted.
1
Software controlled recovery. PWM resumes control of outputs only after all fault
sources have deasserted and all fault flags are cleared and a PWM reload occurs
[1]
Fault0INT 0
Fault 0 Interrupt
Interrupt on Fault0 pin assertion disabled.
1
Interrupt on Fault0 pin assertion enabled.
[0]
Fault0RST 0
Fault 0 Restart
Automatic recovery. PWM resumes control of outputs when all fault sources have
deasserted.
1
Software controlled recovery. PWM resumes control of outputs only after all fault
sources have deasserted and all fault flags are cleared and a PWM reload occurs
Note: This register can only be written when PWEN is cleared.
Hex Address: F29
.
Table 169. Current-Sense Trigger Control Register (PWMSHC)
BITS
FIELD
RESET
R/W
ADDR
7
CSTPOL
0
R/W
6
HEN
0
R/W
5
NHEN
0
R/W
4
3
LEN
NLEN
0
0
R/W
R/W
F29H
2
1
0
CSTPWM2 CSTPWM1 CSTPWM0
0
0
0
R/W
R/W
R/W
PS024604-1005
PRELIMINARY
Appendix A—Register Tables