Z8FMC16100 Series Flash MCU
Product Specification
141
Table 77. LIN-UART Baud Rate Low Byte Register (U0BRL)
BITS
7
6
5
4
3
2
1
0
FIELD
BRL
RESET
FFH
R/W
R/W
ADDR
F47H
The LIN-UART data rate is calculated using the following equation for standard UART
modes. For LIN protocol, the Baud Rate registers must be programmed with the baud
period rather than 1/16 baud period.
Note: The UART must be disabled when updating the Baud Rate registers because the high and
low registers must be written independently.
The LIN-UART data rate is calculated using the following equation for standard UART
operation:
System Clock Frequency (Hz)
UART Data Rate (bits per second) =
16 x UART Baud Rate Divisor Value
The LIN-UART data rate is calculated using the following equation for LIN mode UART
operation:
System Clock Frequency (Hz)
UART Data Rate (bits per second) =
UART Baud Rate Divisor Value
For a given LIN-UART data rate, the integer baud rate divisor value is calculated using the
following equation for standard UART operation:
UART Baud Rate Divisor Value (BRG)
=
Ro
und


S--1--y--6-s---x-t-e-U---m--A----RC----T-l-o---cD---k--a---Ft--a--r--e-R--q--a-u---t-ee---n--(-c-b--y--i-t--s(--H-/-s--z-)--)-
For a given LIN-UART data rate, the integer baud rate divisor value is calculated using the
following equation for LIN mode UART operation:
UART Baud Rate Divisor Value (BRG) = RoundS-----y---sU--t--eA----mR-----T-C----D-l-o--a-c---tk-a----F-R---r--ea---qt--e-u----e(--b-n--i-ct--s-y--/--s-(--)H----z---)-
PS024604-1005
PRELIMINARY
LIN-UART Baud Rate High and Low Byte