English
Language : 

Z8FMC16100 Datasheet, PDF (344/402 Pages) Zilog, Inc. – Z8 Encore-R Motor Control Flash MCUs
Z8 Encore!® Motor Control Flash MCUs
Product Specification
322
Bit
Position
[7,6]
Reserved
[5, 3, 1]
OUT2L/
OUT1L/
OUT0L
[4, 2, 0]
OUT2H/
OUT1H/
OUT0H
Value
(H)
0
1
0
1
Description
Must be 0.
PWM 2L/1L/0L Output Configuration
PWM 2L/1L/0L output signal is enabled and controlled by PWM.
PWM 2L/1L/0L output signal is in low-side off-state.
PWM 2H/1H/0H Output Configuration
PWM 2H/1H/0H output signal is enabled and controlled by PWM.
PWM 2H/1H/0H output signal is in high-side off-state.
Hex Address: F28
PWM Fault Control Register (PWMFCTL)
BITS
FIELD
RESET
R/W
ADDR
7
Reserved
0
R/W
6
DBGRST
0
R/W
5
4
3
Fault1INT Fault1RST CMPINT
0
0
0
R/W
R/W
R/W
F28H
2
1
0
CMPRST Fault0INT Fault0RST
0
R/W
R/W
R/W
Bit
Position
[7]
Reserved
[6]
DBGRST
Value
(H)
0
0
1
[5]
Fault1INT 0
1
Description
Reserved.
DebugRestart
Automatic recovery. PWM resumes control of outputs when all fault sources have
deasserted and a new PWM period begins.
Software controlled recovery. PWM resumes control of outputs only after all fault
sources have deasserted and all fault flags are cleared and a PWM reload occurs
Fault 1 Interrupt
Interrupt on comparator assertion disabled.
Interrupt on comparator assertion enabled.
PS024604-1005
PRELIMINARY
Appendix A—Register Tables