English
Language : 

Z8FMC16100 Datasheet, PDF (332/402 Pages) Zilog, Inc. – Z8 Encore-R Motor Control Flash MCUs
Z8 Encore!® Motor Control Flash MCUs
Product Specification
310
Bit
Position
[6–5]
TICONFIG
Value
(H)
[4]
TINSEL 0
1
[3–1]
PWMD
000
001
010
011
100
101
110
111
[0]
INCAP
0
1
Description
Timer Interrupt Configuration—This field configures timer interrupt definitions.
These bits affect all modes. The effect per mode is explained below:
ONE SHOT, CONTINUOUS, COUNTER, PWM, COMPARE, DUAL PWM,
TRIGGERED ONE-SHOT, COMPARATOR COUNTER:
0x Timer interrupt occurs on reload.
10 Timer interrupts are disabled.
11 Timer Interrupt occurs on reload.
GATED:
0x Timer interrupt occurs on reload or inactive gate edge.
10 Timer interrupt occurs on inactive gate edge.
11 Timer interrupt occurs on reload.
CAPTURE, CAPTURE/COMPARE, CAPTURE RESTART:
0x Timer interrupt occurs on reload and capture.
10 Timer interrupt occurs on capture only.
11 Timer interrupt occurs on reload only
Timer Input Select
Timer input is the Timer input pin.
Timer input is the comparator output.
PWM Delay Value
This field is a programmable delay to control the number of additional system
clock cycles following a PWM or Reload compare before the Timer Output or the
Timer Output Complement is switched to the active state. This field ensures a
time gap between the deassertion of one PWM output to the assertion of its
complement.
No delay
2 cycles delay
4 cycles delay
8 cycles delay
16 cycles delay
32 cycles delay
64 cycles delay
128 cycles delay
Input Capture Event
Previous timer interrupt is not a result of a Timer Input Capture Event
Previous timer interrupt is a result of a Timer Input Capture Event.
PS024604-1005
PRELIMINARY
Appendix A—Register Tables