85
PWM Fault Control Register
The PWM Fault Control (PWMFCTL) Register, shown in Table 54, determines how the
PWM recovers from a fault condition. Settings in this register select automatic or software
controlled PWM restart.
Table 54. PWM Fault Control Register (PWMFCTL)
BITS
FIELD
RESET
R/W
ADDR
7
Reserved
0
R/W
6
DBGRST
0
R/W
5
4
3
Fault1INT Fault1RST CMPINT
0
0
0
R/W
R/W
R/W
F28H
2
1
0
CMPRST Fault0INT Fault0RST
0
0
0
R/W
R/W
R/W
Bit
Position
[7]
Reserved
[6]
DBGRST
Value
(H)
0
0
1
[5]
Fault1INT 0
1
[4]
Fault1RST 0
1
[3
CMP0INT 0
1
[2]
CMP0RST 0
1
Description
Reserved.
DebugRestart
Automatic recovery. PWM resumes control of outputs when all fault sources have
deasstered and a new PWM period begins.
Software controlled recovery. PWM resumes control of outputs only after all fault
sources have deasserted and all fault flags are cleared and a PWM reload occurs
Fault 1 Interrupt
Interrupt on comparator assertion disabled.
Interrupt on comparator assertion enabled.
Fault 1 Restart
Automatic recovery. PWM resumes control of outputs when all fault sources have
deasstered.
Software controlled recovery. PWM resumes control of outputs only after all fault
sources have deasserted and all fault flags are cleared and a PWM reload occurs
Comparator 0 Interrupt
Interrupt on comparator 0 assertion disabled.
Interrupt on comparator 0 assertion enabled.
Comparator 0 Restart
Automatic recovery. PWM resumes control of outputs when all fault sources have
deasstered.
Software controlled recovery. PWM resumes control of outputs only after all fault
sources have deasserted and all fault flags are cleared and a PWM reload occurs
PS024604-1005
PRELIMINARY
PWM Fault Control Register