English
Language : 

Z8FMC16100 Datasheet, PDF (126/402 Pages) Zilog, Inc. – Z8 Encore-R Motor Control Flash MCUs
Z8 Encore!® Motor Control Flash MCUs
Product Specification
104
Timer 0 Reload High and Low Byte Registers
The Timer 0 Reload High and Low Byte (T0RH and T0RL) registers, shown in Tables 60
and 61, store a 16-bit reload value, {TRH[7:0], TRL[7:0]}. Values written to the Timer
Reload High Byte Register are stored in a temporary holding register. When a Write to the
Timer Reload Low Byte Register occurs, the temporary holding register value is written to
the Timer High Byte Register. This operation allows simultaneous updates of the 16-bit
timer reload value.
Table 60. Timer 0 Reload High Byte Register (T0RH)
BITS
7
6
5
4
3
2
1
0
FIELD
TRH
RESET
FFH
R/W
R/W
ADDR
F02H
Table 61. Timer 0 Reload Low Byte Register (T0RL)
BITS
7
6
5
4
3
2
1
0
FIELD
TRL
RESET
FF
R/W
R/W
ADDR
F03H
TRH and TRL—Timer Reload Register High and Low
These two bytes form the 16-bit Reload value, {TRH[7:0], TRL[7:0]}. This value sets the
maximum count value which initiates a timer reload to 0001H.
General-Purpose Timer
PRELIMINARY
PS024604-1005