English
Language : 

MC9S12NE64CPVE Datasheet, PDF (324/554 Pages) Freescale Semiconductor, Inc – MC9S12NE64 Device Overview
Chapter 11 Ethernet Media Access Controller (EMACV1)
WDATA — MII Management Write Data
This data field contains the write data to be used when sourcing a write MII management frame.
11.3.2.13 MII Management Read Data (MRDATA)
Module Base + $14
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
R
RDATA
W
RESET: 0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 11-14. MII Management Read Data (MRDATA)
Read: Anytime.
Write: Never.
RDATA — MII Management Read Data
This data field contains the read data resulting from a read MII management frame. RDATA is valid
only when MMCIF is set after a valid read frame operation.
11.3.2.14 MII Management Command and Status (MCMST)
Module Base + $16
7
6
5
4
3
2
1
0
R
0
0
BUSY
W
OP
NOPRE
MDCSEL
RESET:
0
0
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 11-15. MII Management Command and Status (MCMST)
Read: Anytime.
Write: See each bit description.
OP — Operation Code
This field must be programmed to 10 to generate a valid read frame operation. See Section 11.4.6.2,
“Read Operation.” This field must be programmed to 01 to generate a valid write frame operation. See
Section 11.4.6.3, “Write Operation.” A programmed value of 00, 11, or any value programmed while
BUSY is set is ignored. While programming MCMST, the OP write is ignored if MDCSEL is a 0
value. This field always reads 00.
MC9S12NE64 Data Sheet, Rev. 1.1
324
Freescale Semiconductor