English
Language : 

W90P710CD Datasheet, PDF (450/552 Pages) Winbond – 32-BIT ARM7TDMI-BASED MCU
W90P710CD/W90P710CDG
Contiuned
BITS
[2]
CDP
[1:0] RESERVED
DESCRIPTIONS
Card Detect Polarity.
We can use the CDP bit to choose the card present input polarity for
different socket application.
0 : the input high means card is present.
1 : the input low means card is present.
-
Smart Card Host Clock Base Register (SCHI_CBR)
REGISTER
SCHI_CBR0
SCHI_CBR1
ADDRESS
0xFFF8_5010
0xFFF8_5810
R/W
DESCRIPTION
R/W Clock base Register 0
R/W Clock base Register 1
31
30
29
28
27
26
RESERVED
23
22
21
20
19
18
RESERVED
15
14
13
12
11
10
RESERVED
7
6
5
4
3
2
8-bit clock base Data
RESET VALUE
0x0000_000C
0x0000_00OC
25
24
17
16
9
8
1
0
BITS
[31:8]
RESERVED
[7:0]
CBR
DESCRIPTIONS
-
Clock Base value.
It specifies number of internal sampling clock pulses for a data bit.
Default to be 0Ch.
This register combining with BLH and BLL (baud rate latches)
determine internal sampling clock frequency. For example, CBR
defaults to be 0Ch and BLH, BLL default to be 1Fh which mean
SCCLK clock frequency is 372 (12 x 31) times of internal sampling
clock frequency. The default values of CBR, BLH and BLL are
corresponding to default values of transmission factors F and D
specified in ISO/IEC 7816-3. The value of 0Ch of CBR means
there're 12 sampling clock pulses to detect a 1-etu (elementary
time unit) data bit on SCIO signal. It is recommended that user
sets CBR to be around 16 to maintain better data integrity and
transmission stability.
- 450 -