English
Language : 

W90P710CD Datasheet, PDF (423/552 Pages) Winbond – 32-BIT ARM7TDMI-BASED MCU
W90P710CD/W90P710CDG
BITS
[31:2]
[1]
[0]
DESCRIPTION
RESERVED -
Interrupt 5 status
INT5
When interrupt input is detected with ISTYPE5 triggered condition, this
flag will be set. It must be cleared by software.
1 = interrupt detected.
0 = No interrupt
Interrupt 4 status
INT4
When interrupt input is detected with ISTYPE4 triggered condition, this
flag will be set. It must be cleared by software.
1 = interrupt 4 is detected.
0 = no interrupt
Publication Release Date: September 19, 2006
- 423 -
Revision B2