English
Language : 

HC1S25 Datasheet, PDF (38/110 Pages) Altera Corporation – HardCopy Stratix Device Family
Recommended Operating Conditions
Table 4–29. 1.5-V Differential HSTL Specifications
Symbol
Parameter
VC CIO
I/O supply voltage
VDIF (DC) DC input differential
voltage
VCM (DC) DC common mode input
voltage
VDIF (AC) AC differential input
voltage
Conditions
Minimum
1.4
0.2
0.68
0.4
Typical
1.5
Maximum Unit
1.6
V
V
0.9
V
V
Table 4–30. CTT I/O Specifications
Symbol
Parameter
Conditions
VC CIO
VTT/VREF
Output supply voltage
Termination and input
reference voltage
VIH
High-level input voltage
VIL
Low-level input voltage
VOH
High-level output voltage IOH = –8 mA
VOL
Low-level output voltage IOL = 8 mA
IO
Output leakage current GND ≤ VOU T ≤
(when output is high Z) VC CI O
Minimum
2.05
1.35
VREF + 0.2
VREF + 0.4
–10
Typical
3.3
1.5
Maximum Unit
3.6
V
1.65
V
V
VREF – 0.2 V
V
VREF – 0.4 V
10
μA
Table 4–31. Bus Hold Parameters
Parameter
Conditions
Low sustaining current VIN > VIL (maximum)
High sustaining current VIN < VIH (minimum)
Low overdrive current 0 V < VIN < VCCIO
High overdrive current 0 V < VIN < VCCIO
Bus hold trip point
VCCIO Level
1.5 V
1.8 V
2.5 V
3.3 V Unit
Min Max Min Max Min Max Min Max
25
30
50
70
μA
–25
–30
–50
–70
μA
160
200
300
500 μA
–160
–200
–300
–500 μA
0.5 1.0 0.68 1.07 0.7 1.7 0.8 2.0 V
4–14
Altera Corporation
September 2008