English
Language : 

C8051F58X Datasheet, PDF (269/356 Pages) Silicon Laboratories – Programmable hysteresis and response time Configurble as interrupt or reset source Low current
C8051F58x/F59x
Table 25.1. Timer Settings for Standard Baud Rates
Using The Internal 24 MHz Oscillator
Target
Baud Rate
(bps)
230400
115200
57600
28800
14400
9600
2400
1200
Baud Rate
% Error
0.16%
0.16%
–0.08%
0.04%
–0.02%
0.00%
0.00%
0.00%
Frequency: 24 MHz
Oscilla- Timer Clock SCA1–SCA0
tor Divide Source
(pre-scale
Factor
select)1
104
SYSCLK
XX2
208
SYSCLK
XX
417
SYSCLK
XX
833
SYSCLK/4
01
1667 SYSCLK/12
00
2500 SYSCLK/12
00
10000 SYSCLK/48
10
20000 SYSCLK/48
10
Notes:
1. SCA1–SCA0 and T1M bit definitions can be found in Section 27.1.
2. X = Don’t care.
T1M1 Timer 1
Reload
Value (hex)
1
0xCC
1
0x98
1
0x30
0
0x98
0
0x30
0
0x98
0
0x98
0
0x30
Rev. 1.2
269