C8051F58X Datasheet, PDF (171/356 Pages) Silicon Laboratories – Programmable hysteresis and response time Configurble as interrupt or reset source Low current
C8051F58x/F59x
18.6.2.2. 8-bit MOVX without Bank Select: EMI0CF[4:2] = 001 or 011
Muxed 8-bit WRITE Without Bank Select
ADDR[15:8]
AD[7:0]
EMIF ADDRESS (8 LSBs) from
R0 or R1
T
ALEH
T
ALEL
EMIF WRITE DATA
ALE
/WR
T
ACS
T
WDS
T
ACW
T
WDH
T
ACH
/RD
ADDR[15:8]
AD[7:0]
ALE
Muxed 8-bit READ Without Bank Select
EMIF ADDRESS (8 LSBs) from
R0 or R1
T
ALEH
T
ALEL
EMIF READ DATA
T
RDS
T
RDH
T
ACS
T
ACW
T
ACH
/RD
/WR
Figure 18.8. Multiplexed 8-bit MOVX without Bank Select Timing
Rev. 1.2
171