MC68HC08AS32 Datasheet, PDF (361/394 Pages) Motorola, Inc – M68HC08 Family of 8-bit microcontroller units (MCUs)
Byte Data Link Controller-Digital (BDLC-D)
BDLC CPU Interface
TSIFR — Transmit Single Byte IFR with No CRC (Type 1 or 2) Bit
The TSIFR bit is used to request the BDLC to transmit the byte in the
BDLC data register (BDR, $003F) as a single byte IFR with no CRC.
Typically, the byte transmitted is a unique identifier or address of the
transmitting (responding) node. See Figure 20-18.
1 = If this bit is set prior to a valid EOD being received with no CRC
error, once the EOD symbol has been received the BDLC will
attempt to transmit the appropriate normalization bit followed
by the byte in the BDR.
0 = The TSIFR bit will be cleared automatically, once the BDLC
has successfully transmitted the byte in the BDR onto the
bus, or TEOD is set, or an error is detected on the bus.
If the programmer attempts to set the TSIFR bit immediately after the
EOD symbol has been received from the bus, the TSIFR bit will remain
in the reset state and no attempt will be made to transmit the IFR byte.
If a loss of arbitration occurs when the BDLC attempts to transmit and
after the IFR byte winning arbitration completes transmission, the BDLC
will again attempt to transmit the BDR (with no normalization bit). The
BDLC will continue transmission attempts until an error is detected on
the bus, or TEOD is set, or the BDLC transmission is successful.
If loss or arbitration occurs in the last two bits of the IFR byte, two
additional 1 bits will not be sent out because the BDLC will attempt to
retransmit the byte in the transmit shift register after the IRF byte winning
arbitration completes transmission.
TMIFR1 — Transmit Multiple Byte IFR with CRC (Type 3) Bit
The TMIFR1 bit requests the BDLC to transmit the byte in the BDLC
data register (BDR) as the first byte of a multiple byte IFR with CRC
or as a single byte IFR with CRC. Response IFR bytes are still subject
to J1850 message length maximums (see 20.5.2 J1850 Frame
Format and Figure 20-18).
If this bit is set prior to a valid EOD being received with no CRC error,
once the EOD symbol has been received the BDLC will attempt to
transmit the appropriate normalization bit followed by IFR bytes. The
MC68HC08AS32 — Rev. 3.0
MOTOROLA
Byte Data Link Controller-Digital (BDLC-D)
Advance Information
361