Timer Interface (TIM)
Clearing the toggle-on-overflow bit, TOVx, inhibits output toggles on TIM
overflows. Subsequent output compares try to force the output to a state
it is already in and have no effect. The result is a 0% duty cycle output.
Setting the channel x maximum duty cycle bit (CHxMAX) and clearing
the TOVx bit generates a 100% duty cycle output. (See 16.9.4 TIM
Channel Status and Control Registers.)
16.5 Interrupts
The following TIM sources can generate interrupt requests:
• TIM overflow flag (TOF) — The TOF bit is set when the TIM
counter value rolls over to $0000 after matching the value in the
TIM counter modulo registers. The TIM overflow interrupt enable
bit, TOIE, enables TIM overflow CPU interrupt requests. TOF and
TOIE are in the TIM status and control register.
• TIM channel flags (CH5F–CH0F) — The CHxF bit is set when an
input capture or output compare occurs on channel x. Channel x
TIM CPU interrupt requests are controlled by the channel x
interrupt enable bit, CHxIE.
16.6 Low-Power Modes
The WAIT and STOP instructions put the MCU in low-power standby
modes.
16.6.1 Wait Mode
The TIM remains active after the execution of a WAIT instruction. In wait
mode, the TIM registers are not accessible by the CPU. Any enabled
CPU interrupt request from the TIM can bring the MCU out of wait mode.
If TIM functions are not required during wait mode, reduce power
consumption by stopping the TIM before executing the WAIT instruction.
Advance Information
218
Timer Interface (TIM)
MC68HC08AS32 — Rev. 3.0
MOTOROLA