Clock Generator Module (CGM)
Functional Description
8. Program the PLL registers accordingly:
a. In the upper four bits of the PLL programming register (PPG),
program the binary equivalent of N.
b. In the lower four bits of the PLL programming register (PPG),
program the binary equivalent of L.
8.4.2.5 Special Programming Exceptions
The programming method described in 8.4.2.4 Programming the PLL
does not account for two possible exceptions. A value of zero for N or L
is meaningless when used in the equations given. To account for these
exceptions:
• A zero value for N is interpreted exactly the same as a value of
one.
• A zero value for L disables the PLL and prevents its selection as
the source for the base clock. (See 8.4.3 Base Clock Selector
Circuit.)
8.4.3 Base Clock Selector Circuit
This circuit is used to select either the crystal clock (CGMXCLK) or the
VCO clock (CGMVCLK) as the source of the base clock (CGMOUT).
The two input clocks go through a transition control circuit that waits up
to three CGMXCLK cycles and three CGMVCLK cycles to change from
one clock source to the other. During this time, CGMOUT is held in
stasis. The output of the transition control circuit is then divided by two
to correct the duty cycle. Therefore, the bus clock frequency, which is
one-half of the base clock frequency, is one-fourth the frequency of the
selected clock (CGMXCLK or CGMVCLK).
The BCS bit in the PLL control register (PCTL) selects which clock drives
CGMOUT. The VCO clock cannot be selected as the base clock source
if the PLL is not turned on. The PLL cannot be turned off if the VCO clock
is selected. The PLL cannot be turned on or off simultaneously with the
selection or deselection of the VCO clock. The VCO clock also cannot
be selected as the base clock source if the factor L is programmed to a
MC68HC08AS32 — Rev. 3.0
MOTOROLA
Clock Generator Module (CGM)
Advance Information
103