English
Language : 

HD6473032F Datasheet, PDF (515/572 Pages) Hitachi Semiconductor – Hitachi Microcomputer
TOCR—Timer Output Control Register
H'91 ITU (all channels)
Bit
7
—
Initial value
1
Read/Write
—
6
5
4
3
—
— XTGD —
1
1
1
1
—
—
R/W
—
2
1
0
—
OLS4 OLS3
1
1
1
—
R/W R/W
Output level select 3
0 TIOCB3, TOCXA4, and TOCXB4 outputs are inverted
1 TIOCB3, TOCXA4, and TOCXB4 outputs are not inverted
Output level select 4
0 TIOCA3, TIOCA4, and TIOCB4 outputs are inverted
1 TIOCA3, TIOCA4, and TIOCB4 outputs are not inverted
External trigger disable
0 Input capture A in channel 1 is used as an external trigger signal in
reset-synchronized PWM mode and complementary PWM mode*
1 External triggering is disabled
Note: * When an external trigger occurs, bits 5 to 0 in TOER are cleared to 0, disabling ITU
output.
500