MC68HC05V12 Datasheet, PDF (161/246 Pages) Freescale Semiconductor, Inc – HCMOS Microcontreller Unit
Freescale Semiconductor, Inc.
Byte Data Link Controller – Digital (BDLC–D)
BDLC Protocol Handler
In any case, if the bus fault is temporary, as soon as the fault is
cleared, the BDLC will resume normal operation. If the bus fault is
permanent, it may result in permanent loss of communication on the
J1850 bus. See 14.7.4 BDLC State Vector Register.
BREAK — Break
If a BREAK symbol is received while the BDLC is transmitting or
receiving, an invalid symbol (in BSVR) interrupt will be generated.
Reading the BSVR (see 14.7.4 BDLC State Vector Register) will
clear this interrupt condition. The BDLC will wait for the bus to idle,
then wait for a start-of-frame (SOF) symbol.
The BDLC cannot transmit a BREAK symbol. It only can receive a
BREAK symbol from the J1850 bus.
14.6.5.5 Summary
Table 14-1. BDLC J1850 Bus Error Summary
Error Condition
Transmission error
Cyclical redundancy check (CRC) error
Invalid symbol: BDLC transmits, but
receives invalid bits (noise)
Framing error
Bus short to VDD
Bus short to GND
BDLC receives BREAK symbol
BDLC Function
For invalid bits or framing symbols on non-byte boundaries, invalid
symbol interrupt will be generated. BDLC stops transmission.
CRC error interrupt will be generated. The BDLC will wait for EOF.
The BDLC will abort transmission immediately. Invalid symbol
interrupt will be generated.
Invalid symbol interrupt will be generated. The BDLC will wait for end
of frame (EOF).
The BDLC will not transmit until the bus is idle. Invalid symbol
interrupt will be generated. EOF interrupt also must be seen
before another transmission attempt. Depending on length of the
short, LOA flag also may be set.
Thermal overload will shut down physical interface. Fault condition is
seen as invalid symbol flag. EOF interrupt must also be seen
before another transmission attempt.
Invalid symbol interrupt will be generated. The BDLC will wait for the
next valid SOF.
MC68HC05V12 — Rev. 2.0
Byte Data Link Controller – Digital (BDLC–D)
For More Information On This Product,
Go to: www.freescale.com
Technical Data