Table 23.9 Control Signal Timing
Condition A: VCC = 5.0 V ±10%, VSS = 0 V, ø = 2.0 MHz to maximum operating frequency,
Ta = –20˚C to +75˚C (regular specifications), Ta = –40˚C to +85˚C (wide-range
specifications)
Condition B: VCC = 4.0 V to 5.5 V, VSS = 0 V, ø = 2.0 MHz to maximum operating frequency,
Ta = –20˚C to +75˚C (regular specifications), Ta = –40˚C to +85˚C (wide-range
specifications)
Condition C: VCC = 2.7 V to 5.5 V*, VSS = 0 V, ø = 2.0 MHz to maximum operating frequency,
Ta = –20˚C to +75˚C
Condition C Condition B
10 MHz
12 MHz
Item
Symbol Min Max Min Max
RES setup time
t RESS
RES pulse width
t RESW
NMI setup time
t NMIS
(NMI, IRQ0 to IRQ7)
NMI hold time
t NMIH
(NMI, IRQ0 to IRQ7)
Interrupt pulse width
t NMIW
for recovery from soft-
ware standby mode
(NMI, IRQ0 to IRQ2, IRQ6)
Crystal oscillator settling tOSC1
time (reset)
300 —
10 —
300 —
10 —
300 —
20 —
200 —
10 —
150 —
10 —
200 —
20 —
Crystal oscillator settling tOSC2
8
—
time (software standby)
8
—
Note: * In the F-ZTAT LH version, VCC = 3.0 V to 5.5 V.
Condition A
16 MHz
Test
Min Max Unit Conditions
200 — ns Fig. 23.9
10 —
150 —
t cyc
ns Fig. 23.10
10 — ns
200 — ns
20 — ms Fig. 23.11
8
— ms Fig. 23.12