41.3.2 Controller Area Network (CAN)
41.3.2.1 CAN: Low Power Mode and Error Frame
If the Low Power Mode is activated while the CAN is generating an error frame, this error frame may be shortened.
Problem Fix/Workaround
None
41.3.2.2 CAN: Low Power Mode and Pending Transmit Messages
No pending transmit messages may be sent once the CAN Controller enters Low-power Mode.
Problem Fix/Workaround
Check that all messages have been sent by reading the related Flags before entering Low-power Mode.
41.3.3 Ethernet MAC (EMAC)
41.3.3.1 EMAC: RMII Mode
RMII mode is not functional.
Problem Fix/Workaround
None
41.3.3.2 EMAC: Possible Event Loss when Reading EMAC_ISR
If an event occurs within the same clock cycle in which the EMAC_ISR is read, the corresponding bit might be cleared
even though it has not been read at 1. This might lead to the loss of this event.
Problem Fix/Workaround
Each time the software reads EMAC_ISR, it has to check the contents of the Transmit Status Register (EMAC_TSR), the
Receive Status Register (EMAC_RSR) and the Network Status Register (EMAC_NSR), as the possible lost event is still
notified in one of these registers.
41.3.3.3 EMAC: Possible Event Loss when Reading the Statistics Register Block
If an event occurs within the same clock cycle during which a statistics register is read, the corresponding counter might
lose this event. This might lead to the loss of the incrementation of one for this counter.
Problem Fix/Workaround
None
41.3.4 Peripheral Input/Output (PIO)
41.3.4.1 PIO: Leakage on PB27 - PB30
When PB27, PB28, PB29 or PB30 (the I/O lines multiplexed with the analog inputs) are set as digital inputs with pull-up
disabled, the leakage can be 25 µA in worst case and 90 nA in typical case per I/O when the I/O is set externally at low
level.
Problem Fix/Workaround
Set the I/O to VDDIO by internal or external pull-up.