35.6.6 ADC Status Register
Register Name:
Access Type:
ADC_SR
Read-only
31
30
29
–
–
–
23
22
21
–
–
–
15
OVRE7
14
OVRE6
13
OVRE5
7
EOC7
6
EOC6
5
EOC5
28
–
20
–
12
OVRE4
4
EOC4
27
–
19
RXBUFF
11
OVRE3
3
EOC3
26
–
18
ENDRX
10
OVRE2
2
EOC2
25
–
17
GOVRE
9
OVRE1
1
EOC1
• EOCx: End of Conversion x
0 = Corresponding analog channel is disabled, or the conversion is not finished.
1 = Corresponding analog channel is enabled and conversion is complete.
• OVREx: Overrun Error x
0 = No overrun error on the corresponding channel since the last read of ADC_SR.
1 = There has been an overrun error on the corresponding channel since the last read of ADC_SR.
• DRDY: Data Ready
0 = No data has been converted since the last read of ADC_LCDR.
1 = At least one data has been converted and is available in ADC_LCDR.
• GOVRE: General Overrun Error
0 = No General Overrun Error occurred since the last read of ADC_SR.
1 = At least one General Overrun Error has occurred since the last read of ADC_SR.
• ENDRX: End of RX Buffer
0 = The Receive Counter Register has not reached 0 since the last write in ADC_RCR or ADC_RNCR.
1 = The Receive Counter Register has reached 0 since the last write in ADC_RCR or ADC_RNCR.
• RXBUFF: RX Buffer Full
0 = ADC_RCR or ADC_RNCR have a value other than 0.
1 = Both ADC_RCR and ADC_RNCR have a value of 0.
24
–
16
DRDY
8
OVRE0
0
EOC0
SAM7X Series [DATASHEET]