Timer Interface Module A (TIMA)
c. Write 1:0 (to clear output on compare) or 1:1 (to set output on
compare) to the edge/level select bits, ELSxB–ELSxA. The
output action on compare must force the output to the
complement of the pulse width level (see Table 22-2).
NOTE:
In PWM signal generation, do not program the PWM channel to toggle
on output compare. Toggling on output compare prevents reliable 0%
duty cycle generation and removes the ability of the channel to self-
correct in the event of software error or noise. Toggling on output
compare can also cause incorrect PWM signal generation when
changing the PWM pulse width to a new, much larger value.
5. In the TIMA status control register (TASC) clear the TIMA stop bit,
TSTOP.
Setting MS0B links channels 0 and 1 and configures them for buffered
PWM operation. The TIMA channel 0 registers (TACH0H–TACH0L)
initially control the buffered PWM output. TIMA status control register 0
(TASC0) controls and monitors the PWM signal from the linked
channels. MS0B takes priority over MS0A.
Setting MS2B links channels 2 and 3 and configures them for buffered
PWM operation. The TIMA channel 2 registers (TACH2H–TACH2L)
initially control the buffered PWM output. TIMA status control register 2
(TASC2) controls and monitors the PWM signal from the linked
channels. MS2B takes priority over MS2A.
Setting MS4B links channels 4 and 5 and configures them for buffered
PWM operation. The TIMA channel 4 registers (TACH4H–TACH4L)
initially control the buffered PWM output. TIMA status control register 4
(TASC4) controls and monitors the PWM signal from the linked
channels. MS4B takes priority over MS4A.
Clearing the toggle-on-overflow bit, TOVx, inhibits output toggles on
TIMA overflows. Subsequent output compares try to force the output to
a state it is already in and have no effect. The result is a 0% duty cycle
output.
Setting the channel x maximum duty cycle bit (CHxMAX) and setting the
TOVx bit generates a 100% duty cycle output (see TIMA Channel
Status and Control Registers on page 402).