EP2SGX30C Datasheet, PDF (173/314 Pages) Altera Corporation – Stratix II GX Device | |||
|
◁ |
DC and Switching Characteristics
Table 4â3. Stratix II GX Device Recommended Operating Conditions (Part 2 of 2) Note (1)
Symbol
Parameter
Conditions
TJ
Operating junction temperature For commercial use
For industrial use
Minimum
0
â40
Maximum Unit
85
C
100
C
Notes to Table 4â3:
(1) Supply voltage specifications apply to voltage readings taken at the device pins, not at the power supply.
(2) During transitions, the inputs may overshoot to the voltage shown in Table 4â2 based upon the input duty cycle.
The DC case is equivalent to 100% duty cycle. During transitions, the inputs may undershoot to â2.0 V for input
currents less than 100 mA and periods shorter than 20 ns.
(3) Maximum VCC rise time is 100 ms, and VCC must rise monotonically from ground to VCC.
(4) VCCPD must ramp-up from 0 V to 3.3 V within 100 μs to 100 ms. If VCCPD is not ramped up within this specified
time, the Stratix II GX device will not configure successfully. If the system does not allow for a VCCPD ramp-up time
of 100 ms or less, hold nCONFIG low until all power supplies are reliable.
(5) All pins, including dedicated inputs, clock, I/O, and JTAG pins, may be driven before VCCINT, VCCPD, and VCCIO
are powered.
(6) VCCIO maximum and minimum conditions for PCI and PCI-X are shown in parentheses.
Transceiver Block Characteristics
Tables 4â4 through 4â6 contain transceiver block specifications.
Table 4â4. Stratix II GX Transceiver Block Absolute Maximum Ratings Note (1)
Symbol
VCCA
VCCP
VCCR
VCCT
VCCT_B
VCCL
VCCH_B
Parameter
Conditions
Transceiver block supply
voltage
Transceiver block supply
voltage
Transceiver block supply
Voltage
Transceiver block supply
voltage
Transceiver block supply
voltage
Transceiver block supply
voltage
Transceiver block supply
voltage
Commercial and
industrial
Commercial and
industrial
Commercial and
industrial
Commercial and
industrial
Commercial and
industrial
Commercial and
industrial
Commercial and
industrial
Minimum Maximum
â0.5
4.6
Units
V
â0.5
1.8
V
â0.5
1.8
V
â0.5
1.8
V
â0.5
1.8
V
â0.5
1.8
V
â0.5
2.4
V
Note to Tables 4â4:
(1) The device can tolerate prolonged operation at this absolute maximum, as long as the maximum specification is
not violated.
Altera Corporation
October 2007
4â3
Stratix II GX Device Handbook, Volume 1
|
▷ |