Table 33: DC Characteristics Over Recommended Operating Conditions
Symbol
Description
Device
Min Max Units
VDRINT
VDRI
IREF
IL
CIN
IRPU
IRPD
IBATT
Data retention VCCINT voltage
Data retention VCCAUX voltage
VREF current per bank
Input leakage current
Input capacitance
Pad pull-up (when selected) @ VIN = 0V, VCCO = 3.3V (sample tested)
Pad pull-down (when selected) @ VIN = 3.6V (sample tested)
Battery supply current
All
1.2
V
All
2.5
V
All
–10 +10
μA
All
–10 +10
μA
All
10
pF
All
Note 1 250
μA
All
Note 1 250
μA
All
100
nA
Notes:
1. Internal pull-up and pull-down resistors guarantee valid logic levels at unconnected input pins. These pull-up and pull-down resistors do not
guarantee valid logic levels when input pins are connected to other circuits.
Table 34: Quiescent Supply Current
Symbol
Description
ICCINTQ Quiescent VCCINT supply current
ICCOQ Quiescent VCCO supply current(1)(2)
ICCAUXQ Quiescent VCCAUX supply current(1)(2)
Device
XQ2V1000
XQ2V3000
XQ2V6000
XQ2V1000
XQ2V3000
XQ2V6000
XQ2V1000
XQ2V3000
XQ2V6000
Min Typical Max Units
12
500
–
27 1300 mA
45 1500
1
6.25
–
2
6.25 mA
2
6.25
5
40
–
10
105 mA
12.5 150
Notes:
1. With no output current loads and no active input pull-up resistors. All I/O pins are 3-stated and floating.
2. If DCI or differential signaling is used, more accurate values can be obtained by using the Power Estimator or XPOWER.
3. Data are retained even if VCCO drops to 0V.
4. All values shown reflect the military temperature operating range. For industrial temperature operating range values, refer to [Ref 4].
Power-On Power Supply Requirements
Xilinx FPGAs require a certain amount of supply current
during power-on to ensure proper device operation. The
actual current consumed depends on the power-on ramp
rate of the power supply.
The VCCINT, VCCAUX, and VCCO power supplies shall each
ramp on no faster than 200 μs and no slower than 50 ms.
Ramp on is defined as: 0 VDC to minimum supply voltages.
Table 35 shows the maximum current required by QPro
Virtex-II FPGAs for proper power on and configuration.
Power supplies can be turned on in any sequence.
If any VCCO bank powers up before VCCAUX, then each bank
draws up to 300 mA, worst case, until the VCCAUX powers
on. This current draw does not harm the device. If the
current is limited to the minimum value above, or larger, the
device powers on properly after all three supplies have
passed through their power on reset threshold voltages.
Note: The 300 mA is transient current (peak) and eventually
disappears even if VCCAUX does not power up
Once initialized and configured, use the power calculator to
estimate current drain on these supplies.
Table 35: Maximum Power-On Current Required for
QPro Virtex-II Devices
Current
Device (mA)
XQ2V1000 XQ2V3000 XQ2V6000
ICCINTMAX
500
ICCAUXMAX
140
ICCOMAX
75
1300
140
140
1500
140
140
Notes:
1. ICCOMIN values listed here apply to the entire device (all banks).
2. All values shown reflect the military temperature operating range.
For industrial temperature operating range values, refer to [Ref 4].
DS122 (v2.0) December 21, 2007
www.xilinx.com
Product Specification
49