Bit 2: MSBE. This bit defines the number of stop bits in each serial character that is transmitted or
received.
(1) If MSBE is set to logical 0, one stop bit is sent and checked.
(2) If MSBE is set to logical 1 and the data length is 5 bits, one-and-a-half stop bits are sent and
checked.
(3) If MSBE is set to logical 1 and the data length is 6, 7, or 8 bits, two stop bits are sent and
checked.
Bits 0 and 1: DLS0, DLS1. These two bits define the number of data bits that are sent or checked in
each serial character.
DLS1
0
0
1
1
DLS0
0
1
0
1
DATA LENGTH
5 bits
6 bits
7 bits
8 bits
The following table identifies the remaining UART registers. Each one is described separately in the
following sections.