English
Language : 

W83627DHG Datasheet, PDF (110/268 Pages) Winbond – WINBOND LPC I/O
W83627DHG
8.77 AUXTIN Temperature Sensor Temperature (High Byte) Register - Index 50h
(Bank 2)
Register Location:
50h
Attribute:
Read Only
Size:
8 bits
7 6 5 432 1 0
TEMP<8:1>
Bit 7: Temperature <8:1> of the AUXTIN sensor. The nine-bit value is in units of 0.5°C.
8.78 AUXTIN Temperature Sensor Temperature (Low Byte) Register - Index 51h
(Bank 2)
Register Location:
51h
Attribute:
Read Only
Size:
8 bits
7 6 5 4 32 1 0
Reserved
TEMP<0>
Bit 7: Temperature <0> of the AUXTIN sensor. The nine-bit value is in units of 0.5°C.
Bit 6-0: Reserved.
8.79 AUXTIN Temperature Sensor Configuration Register - Index 52h (Bank 2)
Register Location:
52h
Power on Default Value: 00h
Attribute:
Read/Write
Size:
8 bits
Publication Release Date: Aug, 22, 2007
-98-
Version 1.4