English
Language : 

W83627DHG Datasheet, PDF (102/268 Pages) Winbond – WINBOND LPC I/O
W83627DHG
8.60 CPUFANOUT1 Start-up Value Register - Index 65h (Bank 0)
Register Location:
65h
Power on Default Value: 01h
Attribute:
Read/Write
Size:
8 bits
7 6 5 4 32 1 0
CPUFANOUT1 Start-up Value
In Thermal CruiseTM mode, CPUFANOUT1 value increases from zero to this eight-bit register value to
provide a minimum value to turn on the fan.
8.61 CPUFANOUT1 Stop Time Register - Index 66h (Bank 0)
Register Location:
66h
Power on Default Value: 3Ch
Attribute:
Read/Write
Size:
8 bits
7 6 5 4 32 1 0
CPUFANOUT1 Stop Time
In Thermal CruiseTM mode or SMART FANTM III mode, if the stop value is enabled, this register
determines the amount of time it takes the CPUFANOUT1 value to fall from the stop value to zero.
(1)For PWM output:
The units are intervals of 0.1 second. The default time is 6 seconds.
(2)For DC output:
The units are intervals of 0.4 second. The default time is 24 seconds.
Publication Release Date: Aug, 22, 2007
-90-
Version 1.4