22. Usage Notes
22.11.2 CAN Transceiver in Boot Mode
When programming the flash memory in boot mode via CAN bus, the operation mode of CAN transceiver
should be set to “high-speed mode” or “normal operation mode”. If the operation mode is controlled by the
MCU, CAN transceiver must be set the operation mode to “high-speed mode” or “normal operation mode”
before programming the flash memory by changing the switch etc. Tables 22.3 and 22.4 show pin con-
nections of CAN transceiver.
Table 22.3 Pin Connections of CAN Transceiver (In case of PCA82C250: Philips product)
Standby mode
Rs pin (Note 1) “H”
CAN communication impossible
Connection
M16C/29
PCA82C250
“L”
possible
High-speed mode
M16C/29
PCA82C250
CTx0
CRx0
TxD CANH
RxD CANL
CTx0
CRx0
TxD CANH
RxD CANL
Port (2)
Rs
Port (2)
Rs
Switch OFF
Switch ON
Note 1: The pin which controls the operation mode of CAN transceiver.
Note 2: Connect to enabled port to control CAN transceiver.
Table 22.4 Pin Connections of CAN Transceiver (In case of PCA82C252: Philips product)
_______
STB pin (Note 1) “L”
Sleep mode
Normal operation mode
“H”
EN pin (Note 1) “L”
“H”
CAN communication impossible
possible
Connection
M16C/29
PCA82C252
M16C/29
PCA82C252
CTx0
CRx0
TxD CANH
RxD CANL
CTx0
CRx0
TxD CANH
RxD CANL
Port (2)
STB
Port (2)
STB
Port (2)
EN
Port (2)
EN
Switch OFF
Switch ON
Note 1: The pin which controls the operation mode of CAN transceiver.
Note 2: Connect to enabled port to control CAN transceiver.
Rev. 1.12 Mar.30, 2007 page 444 of 458