Analog Subsystem
A/D Conversion Methods
cleared when the device is reset, the MC68HC705JJ7/MC68HC705JP7
starts with the charge and discharge function disabled.
The length of time required to reach the maximum voltage to be
measured and the speed of the time counting mechanism will determine
the resolution of the reading. The time to ramp the external capacitor
voltage to match the maximum voltage is dependent on:
• Charging current to external capacitor
• Value of the external capacitor
• Clock rate for timing function
• Any prescaling of the clock to the timing function
• Desired resolution
The charging behavior is described by the general equation:
Where:
tCHG = CEXT x VX / ICHG
tCHG = Charge time (seconds)
CEXT = Capacitance (µF)
VX = Unknown voltage (volts)
ICHG = Charge current (µA)
Since the MCU can measure time in a variety of ways, the resolution of
the conversion will depend on the length of the time keeping function and
its prescaling to the oscillator frequency (fOSC). Therefore, the charge
time also equals:
Where:
tCHG = P x N / fOSC
P = Prescaler value (÷ 2, ÷ 4, ÷ 8, etc.)
N = Number of counts during charge time
fOSC = Oscillator clock frequency (Hz)
MC68HC705JJ7 • MC68HC705JP7 — REV 4