PXB4330 Datasheet, PDF (100/201 Pages) Infineon Technologies AG – ICs for Communications | |||
|
◁ |
PXB 4330
Register WAR.DwordSel(1:0) = â01â:
Register Descriptions
Bit
15
14
13
12
11
10
9
8
TrafClassMax(7:0)
Bit
7
6
5
4
3
2
1
0
SbMaxEpdCi(7:0)
TrafClassMax
(7:0)
Maximum Traffic Class Fill Threshold (determines the maximum
number of cells in all queues associated with this traffic class). The
threshold is defined with a granularity of 256:
Threshold = TrafClassMax(7:0) * 256 Cells
SbMaxEpdCi
(7:0)
Combined Threshold of the Maximum Number of Buffered
Cells in the Scheduler; that is, all cells which are in the traffic
classes (= cells in the corresponding queues) of the Scheduler) for
the following cases:
a) If EPDen=0 and ABRen=0
â Maximum Scheduler fill threshold for CLP=â0/1â cells
b) If EPDen=1 and ABRen=0
â EPD Scheduler threshold
c) If ABRen=1
â CI Scheduler threshold for ABR connections
(Set CI-Bit (Congestion Indication) in the RM cells)
The threshold is defined with a granularity of 256:
Threshold = SbMaxEpdCi(7:0) * 256 Cells
Data Sheet
6-100
09.99
|
▷ |