SLLS956 – DECEMBER 2008
BIT(s)
37378.15:0
ADDRESS: 0x9202
NAME
Die ID [95:80]
Table 2-64. DIE_ID_5
DEFAULT: 0x0000
DESCRIPTION
Bits [95:80] of the Die ID. Unique TI DIE identifier.
ACCESS
RO
BIT(s)
37379.15:0
ADDRESS: 0x9203
NAME
Die ID [79:64]
Table 2-65. DIE_ID_4
DEFAULT: 0x0000
DESCRIPTION
Bits [79:64] of the Die ID. Unique TI DIE identifier.
ACCESS
RO
BIT(s)
37380.15:0
ADDRESS: 0x9204
NAME
Die ID [63:48]
Table 2-66. DIE_ID_3
DEFAULT: 0x0000
DESCRIPTION
Bits [63:48] of the Die ID. Unique TI DIE identifier.
ACCESS
RO
BIT(s)
37381.15:0
ADDRESS: 0x9205
NAME
Die ID [47:32]
Table 2-67. DIE_ID_2
DEFAULT: 0x0000
DESCRIPTION
Bits [47:32] of the Die ID. Unique TI DIE identifier.
ACCESS
RO
BIT(s)
37382.15:0
ADDRESS: 0x9206
NAME
Die ID [31:16]
Table 2-68. DIE_ID_1
DEFAULT: 0x0000
DESCRIPTION
Bits [31:16] of the Die ID. Unique TI DIE identifier.
ACCESS
RO
BIT(s)
37383.15:0
ADDRESS: 0x9207
NAME
Die ID [15:0]
Table 2-69. DIE_ID_0
DEFAULT: 0x0000
DESCRIPTION
Bits [15:0] of the Die ID. Unique TI DIE identifier.
ACCESS
RO
BIT(s)
37384.8
37384.4:0
ADDRESS: 0x9208
NAME
EFC ready
EFC error[4:0]
Table 2-70. EFUSE_STATUS
DEFAULT: 0x0000
DESCRIPTION
When high, indicates that EFUSE autoload operation has completed.
Efuse error bus. Updated when EFC_ready goes high or when instruction
is complete. Non-zero value indicates error condition.
ACCESS
RO
BIT(s)
37385.15
ADDRESS: 0x9209
NAME
EFUSE Auto Load Enable
Table 2-71. EFUSE_CONTROL
DEFAULT: 0x0000
DESCRIPTION
When high, re-enables EFUSE Auto load function. Needs to set back to
low to complete Auto load function.
ACCESS
RW
Submit Documentation Feedback
Detailed Description