EP3C5E144C8N Datasheet, PDF (287/348 Pages) Altera Corporation – Ability to disable external JTAG port | |||
|
◁ |
Chapter 1: Cyclone III Device Data Sheet
1â7
Electrical Characteristics
The OCT resistance may vary with the variation of temperature and voltage after
calibration at device power-up. Use Table 1â8 and Equation 1â1 to determine the final
OCT resistance considering the variations after calibration at device power-up.
Table 1â8 lists the change percentage of the OCT resistance with voltage and
temperature.
Table 1â8. Cyclone III Devices OCT Variation After Calibration at Device Power-Up
Nominal Voltage
dR/dT (%/°C)
dR/dV (%/mV)
3.0
0.262
â0.026
2.5
0.234
â0.039
1.8
0.219
â0.086
1.5
0.199
â0.136
1.2
0.161
â0.288
Equation 1â1. (1), (2), (3), (4), (5), (6)
ÎRV = (V2 â V1) Ã 1000 Ã dR/dV (7)
ÎRT = (T2 â T1) Ã dR/dT (8)
For ÎRx < 0; MFx = 1/ (|ÎRx|/100 + 1) (9)
For ÎRx > 0; MFx = ÎRx/100 + 1 (10)
MF = MFV Ã MFT (11)
Rfinal = Rinitial à MF (12)
Notes to Equation 1â1:
(1) T2 is the final temperature.
(2) T1 is the initial temperature.
(3) MF is multiplication factor.
(4) Rfinal is final resistance.
(5) Rinitial is initial resistance.
(6) Subscript à refers to both V and T.
(7) ÎRV is variation of resistance with voltage.
(8) ÎRT is variation of resistance with temperature.
(9) dR/dT is the change percentage of resistance with temperature after calibration at device power-up.
(10) dR/dV is the change percentage of resistance with voltage after calibration at device power-up.
(11) V2 is final voltage.
(12) V1 is the initial voltage.
December 2011 Altera Corporation
Cyclone III Device Handbook
Volume 2
|
▷ |