English
Language : 

EP3C5E144C8N Datasheet, PDF (284/348 Pages) Altera Corporation – Ability to disable external JTAG port
1–4
Chapter 1: Cyclone III Device Data Sheet
Electrical Characteristics
Recommended Operating Conditions
This section lists the functional operation limits for AC and DC parameters for
Cyclone III devices. The steady-state voltage and current values expected from
Cyclone III devices are provided in Table 1–3. All supplies must be strictly monotonic
without plateaus.
Table 1–3. Cyclone III Devices Recommended Operating Conditions (1), (2)
Symbol
Parameter
Conditions
Min Typ Max Unit
VCCINT (3)
Supply voltage for internal logic
—
1.15 1.2 1.25
V
Supply voltage for output buffers, 3.3-V
operation
—
3.135 3.3 3.465 V
Supply voltage for output buffers, 3.0-V
operation
—
2.85
3
3.15
V
Supply voltage for output buffers, 2.5-V
operation
—
2.375 2.5 2.625 V
VCCIO (3), (4)
Supply voltage for output buffers, 1.8-V
operation
—
1.71 1.8 1.89
V
Supply voltage for output buffers, 1.5-V
operation
—
1.425 1.5 1.575 V
Supply voltage for output buffers, 1.2-V
operation
—
1.14 1.2 1.26
V
VCCA (3)
VCCD_PLL (3)
VI
VO
Supply (analog) voltage for PLL
regulator
Supply (digital) voltage for PLL
Input voltage
Output voltage
—
—
—
—
For commercial use
2.375 2.5 2.625 V
1.15 1.2 1.25
V
–0.5 —
3.6
V
0
—
VCCIO
V
0
—
85
°C
For industrial use
–40
—
100
°C
TJ
Operating junction temperature
For extended temperature –40
—
125
°C
For automotive use
–40
—
125
°C
tRAMP
Power supply ramp time
Standard power-on reset
(POR) (5)
50 µs
—
50 ms
—
Fast POR (6)
50 µs — 3 ms —
IDiode
Magnitude of DC current across
PCI-clamp diode when enabled
—
—
—
10
mA
Notes to Table 1–3:
(1) VCCIO for all I/O banks must be powered up during device operation. All VCCA pins must be powered to 2.5 V (even when PLLs are not used), and
must be powered up and powered down at the same time.
(2) VCCD_PLL must always be connected to VCCINT through a decoupling capacitor and ferrite bead.
(3) The VCC must rise monotonically.
(4) All input buffers are powered by the VCCIO supply.
(5) POR time for Standard POR ranges between 50–200 ms. Each individual power supply should reach the recommended operating range within
50 ms.
(6) POR time for Fast POR ranges between 3–9 ms. Each individual power supply should reach the recommended operating range within 3 ms.
Cyclone III Device Handbook
Volume 2