English
Language : 

AK4679EG Datasheet, PDF (89/220 Pages) Asahi Kasei Microsystems – 24bit Stereo CODEC with DSP and MIC/RCV/HP/SPK/LINE-AMP
[AK4679]
(1-2) Dynamic Volume Control Curve
The inflection points of the DVLC curve is set by three coordinate values (VL1X5-0, VL1Y5-0, VL2X5-0, VL2Y5-0,
VL3X4-0 and VL3Y4-0 bits). The setting of three inflection points are calculated the values of (X1L, Y1L), (X2L, Y2L),
(X3L, Y3L) in dB. The inflection points should be set in such a way that VL1X ≤ VL2X ≤ VL3X, VL1Y ≤ VL2Y ≤ VL3Y.
And the each slope is set by L1G6-0, L2G6-0, L3G6-0 and L4G6-0 bits. X4L is fixed full-scale, Y4L is calculated by the
L4G value. The initial value of the DVLC gain is set by the L1G.
Full scale
(X3L, Y3L)
(X2L, Y2L)
L3G
L4G
(X4L, Y4L)
(X1L, Y1L)
L2G
L1G
(0, 0)
DVLC Input Level
Full scale
Figure 70. DVLC Curve for Low Frequency Range
VL1X/Y5-0 bits Dynamic Volume Control Point
VL2X/Y5-0 bits
[dBFS]
Step
00H
0
(default)
01H
−1.5
02H
−3.0
1.5dB
:
:
2EH
−69.0
2FH
−70.5
30H
N/A
:
:
N/A
3FH
N/A
Table 50. DVLC Point Setting for X/Y1, X/Y2 (N/A: Not available)
VL3X/Y4-0 bits
00H
01H
02H
:
1EH
1FH
Dynamic Volume Control Point
[dBFS]
Step
0
−1.5
−3.0
1.5dB
:
−45.0
−46.5
Table 51. DVLC Point Setting for X/Y3
(default)
MS1402-E-06
- 89 -
2013/02