6.1 Absolute Maximum Ratings
Over operating free-air temperature range (unless otherwise noted)(1)(2)
Supply voltage
LVCMOS IO voltage
Junction temperature
Storage temperature, Tstg
VDD11
VDD18
VDDIO
MIN
MAX
UNIT
–0.3
1.8
V
–0.3
2.5
V
–0.3
4
V
–0.3
VDDIO + 0.3
V
150
°C
–65
150
°C
(1) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office or Distributors for availability and
specifications.
(2) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
6.2 ESD Ratings – JEDEC
V(ESD) Electrostatic discharge
Human body model (HBM), per AEC
Q100-002 (1)
RIN[3:0]+, RIN[3:0]-
Other pins
Charged device model (CDM), per AEC Q100-011
VALUE
±8000
±4000
±1000
(1) AEC Q100-002 indicates HBM stressing is done in accordance with the ANSI/ESDA/JEDEC JS-001 specification.
UNIT
V
6.3 ESD Ratings – IEC and ISO
V(ESD) Electrostatic discharge
ESD Rating (IEC 61000-4-2)
RD= 330 Ω, CS = 150 pF
ESD Rating (ISO 10605)
RD= 330 Ω, CS = 150 pF and 330 pF
RD= 2 kΩ, CS = 150 pF and 330 pF
Contact Discharge
(RIN[3:0]+, RIN[3:0]-)
Air Discharge
(RIN[3:0]+, RIN[3:0]-)
Contact Discharge
(RIN[3:0]+, RIN[3:0]-)
Air Discharge
(RIN[3:0]+, RIN[3:0]-)
VALUE
±8000
±18000
±8000
±18000
UNIT
V
V
6.4 Recommended Operating Conditions
Over operating free-air temperature range (unless otherwise noted)
Supply voltage
LVCMOS supply voltage
Operating free-air temperature, TA
MIPI data rate (per CSI-2 lane)
MIPI CSI-2 HS clock frequency
Local I2C frequency, fI2C
VDD11
VDD18
VDDIO
1.8V Option
3.3V Option
MIN
1.045
1.71
1.71
3.0
–40
400
200
NOM
1.1
1.8
1.8
3.3
25
800
400
MAX UNIT
1.155 V
1.89 V
1.89 V
3.6 V
105 °C
1600 Mbps
800 MHz
1 MHz