English
Language : 

SAA7118 Datasheet, PDF (66/169 Pages) NXP Semiconductors – Multistandard video decoder with adaptive comb filter and component video input
Philips Semiconductors
Multistandard video decoder with adaptive
comb filter and component video input
Preliminary specification
SAA7118
Table 21 Bytes stream of the data slicer
NICK
NAME
DID,
SAV,
EAV
SDID
DC(8)
IDI1
IDI2
CS
BC
COMMENT
subaddress
5DH = 00H
subaddress 5DH;
D5 = 1
subaddress 5DH
D5 = 3EH; note 5
subaddress 5DH
D5 = 3FH; note 5
programmable via
subaddress 5EH
check sum byte
valid byte count
D7
D6
D5
D4
D3
D2
D1
D0
NEP(1) EP(2)
0
1
0
FID(3)
I1(4)
I0(4)
NEP
EP
0 D4[5DH] D3[5DH] D2[5DH] D1[5DH] D0[5DH]
1
FID(3)
V(6)
H(7)
P3
P2
P1
P0
0
FID(3)
V(6)
H(7)
P3
P2
P1
P0
NEP
EP D5[5EH] D4[5EH] D3[5EH] D2[5EH] D1[5EH] D0[5EH]
NEP
OP(9)
OP
CS6
OP
EP(2)
FID(3)
LN2(10)
CS6
0
DC5
LN8(10)
LN1(10)
CS5
CNT5
DC4
LN7(10)
LN0(10)
CS4
CNT4
DC3
LN6(10)
DT3(11)
CS3
CNT3
DC2
LN5(10)
DT2(11)
CS2
CNT2
DC1
LN4(10)
DT1(11)
CS1
CNT1
DC0
LN3(10)
DT0(11)
CS0
CNT0
Notes
1. NEP = inverted EP (see note 2).
2. EP = Even Parity of bits 5 to 0.
3. FID = 0: field 1; FID = 1: field 2.
4. I1 = 0 and I0 = 0: before line 1; I1 = 0 and I0 = 1: lines 1 to 23; I1 = 1 and I0 = 0: after line 23; I1 = 1 and I0 = 1:
line 24 to end of field.
5. Subaddress 5DH at 3EH and 3FH are used for ITU 656 like SAV/EAV header generation; recommended value.
6. V = 0: active video; V = 1: blanking.
7. H = 0: start of line; H = 1: end of line.
8. DC = Data Count in Dwords according to the data type.
9. OP = Odd Parity of bits 6 to 0.
10. LN = Line Number.
11. DT = Data Type according to table.
2001 May 30
66