English
Language : 

Z8F082ASH020SC Datasheet, PDF (136/244 Pages) Zilog, Inc. – Z8 Encore XP-R F08xA Series with eXtended Peripherals
Z8 Encore! XP® F08xA Series
Product Specification
118
For the reserved values, all input switches are disabled to avoid leakage or other undesir-
able operation. ADC samples taken with reserved bit settings are undefined.
Single-Ended:
0000 = ANA0 (transimpedance amp output when enabled)
0001 = ANA1 (transimpedance amp inverting input)
0010 = ANA2 (transimpedance amp non-inverting input)
0011 = ANA3
0100 = ANA4
0101 = ANA5
0110 = ANA6
0111 = ANA7
1000 = Reserved
1001 = Reserved
1010 = Reserved
1011 = Reserved
1100 = Hold transimpedance input nodes (ANA1 and ANA2) to ground.
1101 = Reserved
1110 = Temperature Sensor.
1111 = Manual Offset Calibration Mode.
Differential (non-inverting input and inverting input respectively):
0000 = ANA0 and ANA1
0001 = ANA2 and ANA3
0010 = ANA4 and ANA5
0011 = ANA1 and ANA0
0100 = ANA3 and ANA2
0101 = ANA5 and ANA4
0110 = ANA6 and ANA5
0111 = ANA0 and ANA2
1000 = ANA0 and ANA3
1001 = ANA0 and ANA4
1010 = ANA0 and ANA5
1011 = Reserved
1100 = Reserved
1101 = Reserved
1110 = Reserved
1111 = Manual Offset Calibration Mode
PS024705-0405
PRELIMINARY
Analog-to-Digital Converter